Description
The BCP-136 ensures 24/7 control of SB status and displays current values of charge (discharge) current and voltage.
-
Specifications
Main specifications
Rated input voltage DC, V
24 (10 to 36)*
Power consumption, W
3.0
Integrated protection
– reverse polarity connection;– overvoltage, overload and SC;
– galvanic isolation of supply mains
Number of connected SB (simultaneous), pcs.
2
Number of ports, pcs.**
2×RS-422 (analog and digital)
Digital interface specifications
Purpose
data exchange with CH-105, PCH-205, BMU‑126
Max. baudrate, bit/s
115200
Galvanic isolation
+
Communication protocol
proprietary
Connected units
CH-105, PCH-205, BMU-126
Analog interface specifications
Purpose
measurement of SB voltage and current passing through SB-138
Galvanic isolation of channels
+
Measurement range Ushunt, mV
80
Measurement range Ubat, V
0 to 36
Current measurement accuracy, А
0.01
Voltage measurement accuracy, V
0.01
Input impedance, MΩ
0.8
Permissible shunt resistance, μм
1 to 9990
Connected units
SB-138 and other shunt-based devices
General specifications
Overall dimensions, mm
211×117×55
Overall dimensions incl. bracket, mm
255.0×143.5×65.0
Protection degree
IP22
Limiting temperature, °С
–60 to +70
Operating temperature, °С
–15 to +55
Mounting
panel;
desk-top on a bracket
Weight, kg
panel
1.46
desk-top on a bracket
1.57
-
Downloads
- Brochures
- BCP-136
-
Support